DEWIN cable transit frames are dimensioned to common 120-frame standards, so a purchasing engineer can qualify a second source without redesigning the enclosure. Weld-in and lightweight compression-integrated families cover most BESS, data centre and switchgear cut-outs.

Specification table

Welded frame family -- RWF30R / RWF50R

Carbon steel (primed) or stainless steel construction. Rating per source selection manual: fire A-class, H-class; water pressure 4 Bar; gas pressure 2.5 Bar.

Model Sealing cavity size Cavity count External dimensions Weight
RWF30R1×1CS 60 × 60 mm 1 120 × 160 mm 2.88 kg
RWF30R2×1CS 120 × 60 mm 1 120 × 220 mm 4.8 kg
RWF30R4×1CS 120 × 120 mm 1 180 × 220 mm 8.32 kg
RWF50R1×1CS 60 × 60 mm 1 120 × 200 mm On request

Cavity counts scale from 1×1 up to multi-cavity 8+8+8×N configurations. Full configurator available on request.

Specification table

Lightweight frame family -- compression-integrated

Each frame is paired with a specific sealing module series. Protection rating and integrated compression are stated only where confirmed.

Model Material Pairs with module Protection rating Integrated compression
RPF Anodized aluminium S2 modules IP68 Yes
RSF Anodized aluminium S3 modules IP68 Yes
RCF Carbon steel galvanised or 304 stainless S3 modules IP55 Yes
RTF Stainless steel S1 modules Not stated Not stated

Cross-reference

Check fit before you switch supplier.

Describe your incumbent frame by cut-out dimension. We confirm the DEWIN equivalent and flag anything that needs verification before quoting.

Your current frame DEWIN equivalent Cut-out size Fit check
120-frame, single cavity 60 × 60 mm RWF30R1×1CS 120 × 160 mm Drop-in, no rework
120-frame, cavity 120 × 60 mm RWF30R2×1CS 120 × 220 mm Drop-in, no rework
Aluminium panel frame, S2-class module RPF Confirm on drawing Verify module pairing

Applications

Where these frames are already in service.

Energy storage

BESS containers

Entries between battery racks and control compartments, sealed against dust, water and fire spread within the frame's rated cavity.

Sizing guide →

Data centre

Modular data centre halls

Dense cable penetrations through prefabricated wall panels, re-openable for later capacity additions without replacing the frame.

Sizing guide →

Switchgear

Switchgear panels

Standard cut-outs mean an existing panel design needs no modification when qualifying DEWIN as a second source.

Sizing guide →

Document downloads

Files an engineer needs before quoting.

Drawing

Dimensioned PDF

Cut-out and cavity layout for the welded and lightweight frame families.

Download

CAD

STEP / DWG file

For enclosure design and clash checking against your panel or wall thickness.

Download

Selection

Frame sizing guide

Match your cavity count and cable diameter range to a frame model.

Download

Imagery

Installed evidence, not lifestyle photography.

Installed detail of a DEWIN cable transit frame in an enclosure
Installed detail
DEWIN cable transit frame photographed on a white background
Product on white
Production line manufacturing DEWIN cable transit frames
Production line

Certification status for this product line is listed on our Certifications page .

Enquiry

Send the frame size or drawing. We check fit before we quote.

Reply within one working day, in English, from an engineer.